MENU

HORIZONTAL CYLINDRICAL DOUBLE DOOR AUTOCLAVE

HORIZONTAL CYLINDRICAL DOUBLE DOOR AUTOCLAVE

Construction : Triple walled with steam jacket, Inner chamber, and separate boiler are made up of Heavy gauge Stainless steel Sheet with leakproof arc welding. The Autoclave has a single-piece door made of stainless steel 316/304. The backplate and ring are also made of thick stainless steel sheets. All the sterilizers are hydraulically tested to 4kg/cm2 pressure. Mounted on a tubular steel frame with ground leveling screwed flanges. The Outer jacket is wrapped with glass wool to minimize the heat losses due to radiation and is covered by a polished stainless steel sheet.

The Steam Generator is made of a heavy stainless steel sheet. Heavy ring mounted in front of the boiler with folding thick stainless steel plate is fitted with heating elements and low water level cutoff device to protect the former from burning out dry. The front folding plate system provides easy cleaning of the deposited scale on the elements and the walls for long life and efficiency. Fitted with water gauge glass for water level indication, water inlet, and outlet valves.

Pressure Control Device Device “PIEZOSTAT” is incorporated in electrically operated sterilizers. It economizes on power consumption and reduces the frequent opening of the steam release valve and thus prevents the release of steam in the room, It cuts off the power supply to heaters when the set pressure is achieved and re-energizes the heating elements when pressure falls below the set point. The heating element is Flanged type is made of high-grade SS 304 material.

Safety Door : Sterilizer has hinged self-locking single piece thick S.S. 316/304 plate door which cannot be opened when under pressure. The self-locking device automatically disengages the thread mechanism when the sterilizer is under pressure to preclude any eventuality of an accident.

Features :

  • Triple Safety: The Sterilizer is provided with triple safety features. At the boiler level by a "Piezostat" which automatically limits the pressure to the required set value and a spring-loaded safety valve in case of its failure which releases the steam to keep pressure within the safety limits. At the chamber level, a spring-loaded safety valve and a dead weight release valve to release the steam in case the pressure exceeds the safety limit. All these safety features function independent of one another and sequentially i.e. one takes over the charge in case of the other’s failure.
  • Prevents the discharge line from choking. The plug is easily removable for daily cleaning.
  • Powerful Ejector for drying sterilized linen circulates air throughout the chamber. The circulating air passes through a corrosion-resistant metallic wool filter.
  • Digital Display is provided to show the chamber temperature.
  • Automatic Vacuum breaker is provided to break vacuum in case of formation of vacuum due to steam condensation.

HORIZONTAL CYLINDRICAL DOUBLE DOOR AUTOCLAVE

MODEL SPECIFICATIONS
MODELAU905-75AU905-98AU905-138AU905-177AU905-251AU905-353
Capacity75 L98 L138 L177 L251 L353 L
Diameter400 mm450 mm400 mm500 mm500 mm600 mm
Depth600 mm600 mm1100 mm900 mm1280 mm1250 mm
Operating Temperature121 to 134°C121 to 134°C121 to 134°C121 to 134°C121 to 134°C121 to 134°C
Operating Pressure15 - 30 PSI15 - 30 PSI15 - 30 PSI15 - 30 PSI15 - 30 PSI15 - 30 PSI
Power Consumption9 Kw9 Kw18 Kw12 Kw18 Kw24 Kw
Voltage440V/50Hz, 3 Ph440V/50Hz, 3 Ph440V/50Hz, 3 Ph440V/50Hz, 3 Ph440V/50Hz, 3 Ph440V/50Hz, 3 Ph
All Autoclaves Hydraulically tested to 4 kg/cm2 pressure.